Pentair UltraTemp Heat Pump Error Codes in Houston: What Each Alarm Means and How to Reset It

A Pentair UltraTemp doesn't show numbered codes. It spells out the problem on its control panel, in alarms like LOW WATER FLOW, HIGH REFRIG and FIVE ALARMS. Here's what each one means, what you can check yourself and when it's a repair, from Pentair's own installation and user's guide.

Redzone Pools repairs Pentair, Hayward and Jandy heat pumps and gas heaters across Cypress, Tomball, Katy, Spring and Greater Houston — licensed, insured, usually same day.

Start here

How to read the alarm on your UltraTemp

A Pentair UltraTemp alarm is a full-word message on the heat pump's control panel that names what stopped it, from low water flow to a failed sensor. There are no numbered codes to look up.

When an alarm is active, the SERVICE light comes on. Press the MENU SELECT button until you reach the Alarm Status screen. ALARM STATUS NONE means there's no alarm right now. From that screen, the DOWN arrow steps back through the last 30 alarms, newest first, which helps when the fault has cleared by the time you look.

The alarms below come from Pentair's guide (Rev. P, 2016). The list varies a little with the age of the unit: a 2012 edition doesn't list SERIAL COMM LOST, and newer editions add LOW AMBIENT TEMP.

Every alarm

What each alarm means

AlarmWhat Pentair says it meansWhat to check
LOW WATER FLOWThe pressure switch sensing water flow is openPump on, filter clean, valves set, and any bypass around the heat pump closed
HIGH REFRIGThe refrigerant high pressure switch is openFlow first, with the same checks, plus the pool's water level. After a long idle period, cycle the unit on and off up to 3 times
LOW REFRIGThe refrigerant low pressure switch is openIf it's cold, wait for it to warm up. Clear debris and shrubs from around the unit. Low refrigerant or a fan fault is a service call
LOW AMBIENT TEMPToo cold for the heat pump, or a defrost that didn't finish within 15 minutes (newer editions)Wait for the ice to melt and the air to warm
HIGH WATER TEMPWater above 107°FTest the water. If it isn't that hot, the sensor or control board needs testing
LOW WATER TEMPWater below 40°FTest the water. If it isn't that cold, it's the sensor, the control board or debris shorting the connections
WATER THERM SHORT / OPENThe water temperature sensor circuit is shorted or openA technician tests the sensor, then the control board
SUCTION TH SHORT / OPENThe defrost sensor circuit is shorted or openA technician tests the sensor, then the control board
BROWNOUTThe 24 VAC supply to the control board is lowA technician. Pentair lists a bad transformer or low supply voltage, which should be 208 to 260 volts
REMOTE POOL/SPAPool and spa remote inputs are energized at the same timeYour automation: only the pool or the spa input should be on
SERIAL COMM LOSTThe control board hasn't had a message from the automation controller for 2 minutesThe automation controller and its connection to the heat pump
FIVE ALARMSFive faults in one hourPress ON/OFF, or it resets itself in an hour. The alarm behind it is the real problem
Not faults

Timers and messages that aren't alarms

Some screens look like a problem but are the heat pump working normally:

  • SENSING WATER TEMP: a 1-minute timer that lets pool water reach the heat pump before it reads the temperature. It starts when water begins to run after a stop or low flow, or when the heat pump is turned on.
  • RESTART DELAY: a 5-minute timer that protects the compressor by stopping it from cycling on and off rapidly.
  • DEFROST DELAY: a 15-minute timer while the unit defrosts.
  • PUMP START DELAY: a 1 to 4 hour timer used with the AutoSet feature.
  • HEAT PUMP RUNTIME: an adjustable timer. When it runs out, the green light goes off and the heat pump stays off.
  • HEAT PUMP CONTROLS LOCKED: the panel is locked. Press MENU SELECT and POOL/SPA together to unlock it.
Reset

How to reset a Pentair UltraTemp

Pentair's guide gives a button reset for one alarm: FIVE ALARMS. Press the ON/OFF button to clear it, or it resets itself in an hour. Then watch the heat pump over the next few minutes and hours, because Pentair says the alarm that comes back is most likely the one that caused it.

HIGH REFRIG has its own step. If the heat pump hasn't run for an extended period, Pentair says to cycle it on and off up to 3 times. If that doesn't correct it, call for service.

For everything else, the fix is the cause, not the button. If the display is blank, start with the breaker.

Flow first

LOW WATER FLOW and HIGH REFRIG usually start with flow

Pentair's first checks are the same for both alarms: the pump has to be on, and enough water has to be moving through the unit. Its minimum is 30 gallons a minute and its maximum is 120.

  • Filter: make sure the filter and skimmers are clean, and backwash if you need to. Dirty or worn filters and clogged lint traps are on Pentair's list.
  • Valves: make sure they're open or in the right positions, and that any external bypass around the heat pump is closed.
  • Air leaks: Pentair says to repair suction air leaks and grease the pump lid O-ring.
  • Water level: check the level in the pool.

If the filter gauge stays high after cleaning, see our guide to filter pressure that stays high after backwashing. On a variable-speed pump, a low speed that's fine for filtering may not move enough water, so check the speed while the heat pump is on.

Pentair also lists low flow when switched to spa mode, a clogged pump impeller, an automatic pool vacuum causing a restriction, a unit plumbed backwards, a heat exchanger clogged with debris and a damaged or clogged internal bypass valve. If it's still showing LOW WATER FLOW with good flow, the pressure switch itself may be bad. Those are jobs for a technician.

Cold weather

LOW REFRIG, defrost and ice on cold mornings

A heat pump heats with the air, so a cold Houston morning can stop it without anything being broken. Pentair lists air and water too cold to operate as a cause of LOW REFRIG, and its fix is to wait until temperatures warm up and see if the unit runs.

The UltraTemp may enter a defrost cycle when the air is around 50°F, if defrost is enabled in the service menu. The compressor stops and the fan keeps running for about 15 minutes. If the refrigerant hasn't warmed up by then, the unit shuts down.

If ice forms on the outer coil, Pentair says to shut the heat pump off and let it thaw, and you can use water at low pressure. Make sure sprinklers aren't spraying the unit and plants aren't blocking the air flow. Ice can also come from a refrigerant leak, so check the alarm status for LOW REFRIG. Our guide to a pool heat pump not heating in cold weather explains how to tell the weather from a real fault.

No alarm showing

When it won't heat and there's no alarm

What you seeWhat Pentair listsWhat to do
Blank display, won't startNo power: a tripped breaker or blown fuse, a faulty transformer or a control failureReset the breaker. Anything else is a service call
Green light on, set above actual, won't startRemote feature on with nothing controlling it, or the wrong pool or spa modePress POOL/SPA to check the active mode, and check the Remote Mode screen if you don't have automation
Fan runs, no cool air from the topThe five-minute safety delay, or a compressor, capacitor, contactor or control board faultGive it five minutes, then call
Compressor starts, then cuts offDebris, an air leak, reversed plumbing, a clogged heat exchanger or bypass, or a compressor or board faultClean the filter and check the valves, then call
Fan not turningA fan relay, capacitor, fan motor or control board faultCall a technician
Water under the unitUsually condensation, at about three to five gallons an hour while it runsKeep the drain holes in the base clear
When to call

When an alarm means a repair

Call when an alarm keeps coming back after the flow checks, when it won't heat on a mild afternoon, and for any sensor, refrigerant, fan or BROWNOUT alarm. Pentair says any service must be done by an authorized service agency person, and warns against internal adjustments inside the heater.

Our heater repairs run from about $200 for a small component to $1,000 or more, and a replacement heat pump is roughly $6,000 to $6,500 installed, so a proper diagnosis comes first.

For a Hayward, see our Hayward heat pump error codes. For a Pentair gas heater, see our MasterTemp error code guide. For everything else, see pool heater repair.

Book a Heat Pump Check
Pool equipment pad with a variable-speed pump and Pentair filter serviced by Redzone Pools in Greater Houston
UltraTemp FAQ

Common questions

Does the Pentair UltraTemp have error codes?

Not numbered ones. It shows full-word alarms on the control panel, such as LOW WATER FLOW, HIGH REFRIG and LOW REFRIG, with the SERVICE light on. The Alarm Status screen shows the current alarm, and the DOWN arrow steps through the last 30.

What does HIGH REFRIG mean on a Pentair UltraTemp?

The refrigerant high pressure switch is open. Pentair lists low water flow first: check that the pump is on, the filter and skimmers are clean and any bypass is closed. If the unit has sat unused for a long time, cycle it on and off up to 3 times. If that doesn't clear it, call for service.

What does LOW REFRIG mean on a Pentair UltraTemp?

The refrigerant low pressure switch is open. On a cold day, the air and water may be too cold, so wait for it to warm up. Otherwise Pentair lists low refrigerant, a faulty fan, a stuck expansion valve or poor air flow through the coil. Clear debris and shrubs, and call a technician for the rest.

How do I reset a Pentair UltraTemp heat pump?

For FIVE ALARMS, press the ON/OFF button, or wait an hour for it to reset itself. Then watch for the alarm that caused it to come back. If the display is blank, check the breaker first.

Why does my UltraTemp say LOW WATER FLOW when the pump is running?

The pressure switch isn't seeing enough flow. Clean the filter, check the valves, close any bypass around the heat pump and repair any air leaks. Pentair lists a minimum of 30 gallons a minute. If it still shows, the switch itself may be bad, which a technician can test.

Why won't my UltraTemp heat when no alarm is showing?

Allow for the 5-minute RESTART DELAY first. Then check that it's in the right pool or spa mode, and that the Remote feature isn't on with nothing controlling it. If it's none of those, Pentair lists faults such as the compressor, contactor or control board, which need a technician.

Heater season

UltraTemp still showing an alarm?

Tell us the alarm on the screen and when it started. If it's flow or the weather, we'll tell you so; if it's a sensor, the fan or the refrigerant, we'll come out and fix it. Licensed, insured, serving Cypress and Greater Houston.